BAOLAIHUA
PRECISIONMANUFACTURING
2026-10-16 11:20:06
Click:
Every shot of plastic has to push air out of a closed steel cavity — and most tools have nowhere near enough room for it to leave. When the air cannot escape, it heats up under compression, and the result shows on the part as burns, short shots, weak weld lines and inconsistent fill.

Figure 1. Mold Venting Design Guide: Prevent Burns and Short Shots.
Venting is one of the cheapest features to design correctly and one of the most expensive to retrofit. This guide covers vent depth by resin, vent location and the vent types that actually work in production.
Poor venting rarely announces itself as "a venting problem". It shows up as a cluster of defects that engineers chase one at a time:
If a tool shows two or more of these at once, measure venting before you touch the process.
It helps to size the problem. A cavity of 200 × 150 × 3 mm has a volume of roughly 90 cm³. At atmospheric pressure that is about 0.09 liters of air — but the melt front does not sweep it out evenly. The air is compressed into the last-fill pockets, and at typical injection pressures those pockets can see several bar of pressure.
A practical rule of thumb: plan for a vent cross-section capable of passing the cavity volume in a few hundred milliseconds, distributed across the parting line rather than concentrated at a single point. A single 10 mm × 0.02 mm vent will not evacuate a 90 cm³ cavity — that is why real tools have vents every 25–50 mm around the perimeter.
Vent depth is a balance: deep enough to pass air, shallow enough that the melt does not flash through it. Depth scales with melt viscosity.
| Resin | Recommended vent depth (mm) | Vent land width (mm) |
|---|---|---|
| PE, PP (low viscosity) | 0.015 – 0.025 | 3 – 6 |
| ABS, HIPS, PS | 0.020 – 0.030 | 3 – 6 |
| PC, PC/ABS | 0.030 – 0.040 | 4 – 8 |
| PA6, PA66 (unfilled) | 0.015 – 0.020 | 3 – 5 |
| PA with 30% glass fiber | 0.020 – 0.030 | 4 – 8 |
| POM | 0.015 – 0.025 | 3 – 6 |
| PMMA | 0.030 – 0.040 | 4 – 8 |
| PVC (rigid) | 0.020 – 0.030 | 3 – 6 |
| TPE / TPU | 0.015 – 0.025 | 3 – 6 |
| LSR (liquid silicone) | 0.002 – 0.005 | 2 – 4 |
Important: the vent land must be a short flat land (typically 0.5–1.0 mm long) at the vent depth, then open out to a full-depth relief channel 0.3–0.5 mm deep that leads to atmosphere. A vent that stays at vent depth for its whole length will clog and never pass air properly.
Vented depth is measured from the cavity surface, and in a tool with a textured cavity the vent must be cut relative to the texture-free steel.
Place vents where the air actually ends up, not where it is convenient to machine.
Mandatory vent locations:
A short-shot study is the fastest way to find them: run the tool at progressively lower fill, and mark where each shot stops. Those flow-front positions are your vent locations on the final shot.
| Vent type | Best for | Notes |
|---|---|---|
| Parting-line vent | General purpose, large parts | Cheapest; needs regular cleaning; easy to add at tryout |
| Ejector-pin vent | Deep pockets, bosses, ribs | Use flats ground on the pin; adds a second function to existing hardware |
| Vent insert / sintered steel | Deep blind pockets, hard-to-reach areas | Porous steel passes gas but not melt; needs periodic cleaning or replacement |
| Vent plug / vent disc | Small local last-fill points | Screw-in, replaceable, good for high-wear areas |
| Core / core-pin vent | Long cores and deep draws | Vent along the core pin flat or through the core |
| Vacuum venting | Large parts, LSR, thin walls, poor-flow materials | Evacuates the whole cavity before injection; highest performance and cost |
| Grooved runner vent | Cold runner ends | Prevents gas being pushed back into the next shot |
For LSR and very low-viscosity materials, standard parting-line vents are effectively useless — the silicone flashes through any vent you can machine reliably. These tools rely on vacuum venting plus carefully lapped shut-offs.
| Symptom | Likely venting cause | Fix |
|---|---|---|
| Burn marks at last fill | Vent too shallow, blocked or missing | Clean or deepen vent; add a vent at that location |
| Short shot despite high pressure | Insufficient vent area, gas back-pressure | Add vents; increase vent count around perimeter |
| Weld line cracking | No vent at the weld location | Add a vent at the weld line; raise melt temperature |
| Matt / glossy patches | Local air trapping and slow cooling | Add local venting near the patch |
| Flash at a vent | Vent too deep for the resin | Reduce vent depth; check for worn vent land |
| Vents block every few thousand shots | Vent land too long, no relief channel | Shorten land; add a full-depth relief that reaches atmosphere |
| Burns appear only at high speed | Vent cannot keep up with fill rate | Increase vent area; consider vacuum venting |
Note that "burn marks" also appear when the melt is simply too hot or the screw is decompressing poorly — always confirm the location matches a last-fill point before blaming venting.
A vent is a consumable feature. It will fill with oil, vaporized additives and degraded resin, and its effective depth will drop below what the drawing says.

Figure 2. Quick reference: the key checks and reference values from this guide.
Venting is a design decision, not a tryout adjustment. Size the vent to the resin, place it where the air actually goes, and give the gas a clear route to atmosphere. Do that and you remove a whole category of defects — burns, short shots, weak welds — before the tool is even cut, and you stop fighting the process on every batch.
Send us a part and we will review your venting plan against the fill pattern and resin before the cavity is machined.
Related Articles