LSR Injection Molding: Process, Tooling and Design Guide for Silicone Parts
LSR Runs Backwards - and That Changes Everything
Liquid silicone rubber (LSR) injection molding inverts the thermoplastic process: the material is kept cold in the runner system and cured in a hot mold (typically 150-200°C). Two liquid components (A and B) are metered 1:1, mixed and injected into the heated cavity where platinum-catalyzed addition cure crosslinks the part in 15-60 seconds. Because cured silicone cannot be re-melted, runners are scrap - which is why proper LSR tooling uses a cold-runner system with valve gates and produces flash-free, waste-free parts.
What Makes LSR Tooling Different
- Cold-runner deck: water-cooled to ~20°C so material never cures in the runner; valve-gated drops for zero waste.
- Vacuum venting: LSR flashes into gaps of 0.005 mm - molds are vacuum-evacuated and parting lines are precision-ground.
- Heating: electric cartridge heaters with multi-zone control hold +/-2°C across the cavity.
- Demolding: no draft needed in theory, but soft silicone tears - ejection uses air assist, brushes or robots, never sharp pins on thin membranes.
- Steel: hardened stainless (S136) resists the abrasion of filler-loaded LSR grades.
Design Rules for LSR Parts
- Wall thickness 0.5-6 mm works; very thin membranes (<0.3 mm) need flow-length review.
- No draft angles required for external surfaces - silicone releases elastically - but undercuts must be stripped carefully.
- Design for flash: even with vacuum venting, plan parting lines away from cosmetic and sealing surfaces.
- For LSR overmolding onto thermoplastics (PC, PA, PBT), verify substrate softening temperature exceeds the cure temperature, and use self-adhesive LSR grades or primers.
- Specify post-curing (typically 2-4 h at 200°C) for medical and food-contact parts to drive off volatiles.
Typical Applications
Medical valves, seals and masks (biocompatibility to ISO 10993/USP Class VI grades), automotive connector seals and grommets (stable -50°C to 200°C), baby care and kitchen products (odor-free, food-grade), keypad and gasket overmolding, and optical silicone lenses. Hardness spans Shore A 5-80 from the same process.
Our LSR Capability
BAOLAIHUA runs LSR injection molding with in-house cold-runner tooling, DFM and mold-flow review for both single-material silicone parts and LSR-overmolded assemblies, under ISO 13485 medical workflow for healthcare programs. Send your drawing for a feasibility review within one business day.
Have a drawing ready? Send your STEP, IGES, X_T, STL or PDF files to help@bao-laihua.com or use our online RFQ form. A manufacturing engineer reviews every project and returns a DFM report with a quotation within one business day.